B-8
Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide
Compaq Confidential – Need to Know Required
Writer: Bryan Hicks Project: Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide Comments: First Draft
Part Number: 380362-003 File Name: i-appb Using Compaq Redundancy Manager in a Single-Server Environment.doc.doc Last Saved On: 8/24/00
12:05 PM
Expanding Capacity
Redundancy Manager does not support the hot-add of logical drives. To add
drives, you must:
1.
Physically add the drives to the RA4000/4100.
2.
Reboot Windows NT on the server to see the new drives.
3.
Run the Array Configuration Utility to configure the drives.
NOTE:
You cannot increase the capacity of an existing Windows NT drive volume, but you
can assign a new drive letter to the extra capacity furnished by the added drives.
4.
Run Windows NT Disk Administrator to assign a drive letter to the
newly created, unused capacity of your RAID volume.
5.
While still running Disk Administrator, format the drives using
Microsoft NTFS.
6.
Run Redundancy Manager.
Summary of Contents for ProLiant Clusters HA/F100
Page 8: ......