Upgrading the ProLiant Clusters HA/F100 and HA/F200
4-7
Compaq Confidential – Need to Know Required
Writer: Bryan Hicks Project: Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide Comments:
Part Number: 380362-003 File Name: e-ch4 Upgrading the ProLiant Clusters HAF100 and HAF200.doc Last Saved On: 8/24/00 12:02 PM
4.
Install the latest drivers and server support software by running the
Compaq Support Paq for Windows 2000 on Node 1:
a.
Insert the SmartStart CD and selecting Start and then Run. In the
dialog box that displays, type
X:\cpqsupsw\ntcsp\setup.exe
where X is
the drive letter associated with your CD-ROM drive.
NOTE:
You can also acquire and run the latest Compaq Support Paq from the Compaq
website (http://www.compaq.com/support).
After the installation is completed, the Compaq Support Paq window
will show, the drivers that were updated and the drivers that were not
installed because a current version of the driver exists on the node or
because a lack of hardware on the node.
5.
Install Windows 2000 Advanced Server Service Pack 1 on Node 1.
6.
Verify that the Cluster Service has started and that Node 1 has rejoined
the cluster. Open Cluster Administrator by clicking Start, Programs,
Administrative Tools, Cluster Administrator. As the Cluster
Administrator opens, an error will display. This error is a result of the
additional resources that Windows 2000 Advanced Server offers
Microsoft Cluster Server. This error will not display when Node 2 is
upgraded to Windows 2000 Advanced Server. From the error screen,
select Yes To All to open Cluster Administrator.
7.
Verify the RA4000 Controller Firmware Version Levels by running the
online Array Configuration Utility on Node 1, selecting the RA4000
Controller and then clicking on the More Information tab. The online
Array Configuration Utility is installed by running the Compaq Support
Paq for Windows 2000 in Step 4 of this migration procedure.
IMPORTANT:
If the firmware version levels are not the same and at version 2.58 or later
then it is strongly recommended that they be updated using the procedure in Step 8. If
you choose not to upgrade the firmware then skip to Step 9.