Moving a Storageset From One Controller to the
Other
Choose Move a Storageset when you want to change the ownership from the
current RAID Array controller to the other. This action is useful if you need to
manually return a failed-over storageset to its Preferred path when Auto-
Failback has been disabled.
There are two methods available to move a storageset.
1.
Click the drive to highlight it in the storage system view.
2.
Drag the drive to the other controller or right click to select the Move To
Other Controller action.
Verifying A Path
Choose Verify a Path when you want SPM to determine the current state of a
path.
To verify a path:
1.
Click the path.
2.
Right click to select the Verify Path action.
SPM will generate a pop-up message when the verification completes to
indicate the result of the operation. No state change will occur as a result of
this operation.
NOTE:
For more information on Secure Path, refer to the Compaq SANworks Secure Path
for Windows 2000 on RAID Array 4000/4100 Installation and Reference Guide.