Modifying Physical Cluster Resources
Removing Shared Storage System
Each cluster node, and the cluster as a whole, depends on the shared storage
for data, log, and, possibly, application program files. If the shared storage is
removed, all clustered applications that are dependent on that shared storage
system will be offline. Clearly, network clients will not have access to the
clustered applications.
NOTE:
These procedures for removing a shared storage system assume that you are
making modifications to a previously configured HA/F100 or HA/F200.
To remove a shared storage from your cluster, follow the steps below:
1.
Use Cluster Administrator to bring offline all cluster groups and cluster
resources including physical disk resources dependent on the
RA4000/4100 you are about to remove from the cluster.
2.
Power off the RA4000/4100 you are about to remove. Remove the
Gigabit Interface Converter (GBIC) and the cable from the Fibre
Channel storage hub or FC-AL switch.
3.
Delete the cluster groups and resources you brought offline in Step 1.
Adding Shared Storage System
A Compaq StorageWorks RAID Array 4000 or 4100 cannot be dynamically
added to the cluster. Follow these steps to add another shared storage system
to an existing cluster.
NOTE:
These procedures for adding a shared storage system assume that you are
making modifications to a previously configured HA/F100 or HA/F200.
1.
Power down one of the cluster servers (Node 2).
2.
Insert the Compaq SmartStart and Support Software CD into the
CD-ROM drive of the other cluster server (Node 1). Power down
Node 1.
3.
Insert all of the SCSI drives into the RA4000/4100.
IMPORTANT:
If using a Compaq ProLiant Cluster HA/F200 with redundant paths, be sure
to attach both array controllers, one to each Fibre Channel storage hub or FC-AL switch.
Summary of Contents for ProLiant Clusters HA/F100