CTD-N Technical Manual
P/N 95F-6000-00 (February 2017)
page 75
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Removing the End Cap
3.
Carefully remove the end cap by grasping
the housing in one hand and the end cap
connector in the other as shown and pulling
straight out. It may be necessary to twist
the end cap slightly while pulling. If neces-
sary, a flat plastic, nonmetallic tool can be
used to pry the end cap from the housing.
Do not use a sharp metallic object,
such as a screwdriver or putty knife, to pry
open the end cap as damage to the end
cap, housing or O-ring could occur.
Disconnecting the JP3 and JP4 In-Line Connectors
4.
Disconnect the in-line connectors JP3 and
JP4 and remove the foam pad as shown, ex-
posing the battery pack.
If the Option 1 and Option 2 connectors are
installed, refer instead to the next photo.
Disconnecting the JP3 and JP4 In-Line Connectors, with Options
Connectors
The Option 1 and Option 2 in-line con-
nectors are shown disconnected for identifi-
cation purposes. You do not have to discon-
nect these connectors if you are only re-
placing the battery pack.