CTD-N Technical Manual
P/N 95F-6000-00 (February 2017)
page 137
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
BDMP
Outputs scans from memory in binary
Usage
BDMP <CR> or <LF>
Operating Modes
Open
Description
The BDMP command outputs and displays scans of recorded data in binary. The number of scans
output is specified by the DLEN command. The data are output in IEEE Standard 4-byte binary
form.
NOTE.
To determine which parameters have been logged, and in which order they were
logged, enter the RDM command. The RDM command displays the number of bytes per
scan.
Returns
See Examples below.
Examples
Enter BDMP <CR> or <LF>
The instrument outputs and displays the number of scans specified by the DLEN command.
See Also
DLEN, DDMP, RDM