3-190
Cisco Broadband Cable Command Reference Guide
OL-1581-08
Chapter 3 Cisco CMTS Show Commands
show diag
Table 3-47
describes the fields displayed by the
show diag
command.
The following is sample output from the
show diag
command that displays revision-level information
for the cable line card (slot 6):
CMTS01#
show diag
Slot 6:
MC11 port adapter, 1 port
Port adapter is analyzed
Port adapter insertion time 02:37:10 ago
Hardware Revision : 1.2
Part Number : 800-02455-02
Board Revision : 03
Deviation Number : 0-3
Fab Version : 03
PCB Serial Number : 00004500239
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Calibration Data : Minimum: -8 dBmV, Maximum: 8 dBmV
Calibration values : 0x5D43 0x3F05 0x1794
Unknown Field (type 0083): 83 FF FF FF
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 F1 41 01 02 C0 46 03 20 00 09 97 02
0x10: 42 30 33 80 00 00 00 03 02 03 C1 8B 30 30 30 30
0x20: 34 35 30 30 32 33 39 03 00 81 00 00 00 00 04 00
Table 3-47 show diag Field Descriptions
Field Description
National clock card with T1 controller
The system has identified the cable clock card.
EEPROM contents at hardware discovery
EEPROM programmed data present when the system
identified the clock card.
Hardware Revision
Version number of the card.
Part Number
The part number of the card.
Board Revision
Revision number (signifying a minor revision) of the
card.
Deviation Number
Revision number (signifying a minor deviation) of the
card.
Fab Version
Manufacturing fabrication version number.
PCB Serial Number
Serial number of the printed circuit board.
RMA Test History
Counter indicating how many times diagnostics have
been performed on this card.
RMA Number
Return material authorization number, which is an
administrative number assigned if the card needs to be
returned for repair.
RMA History
Counter indicating how many times the card has been
returned and repaired.
EEPROM format version
Version number of the EEPROM format.
EEPROM contents (hex)
Dumps of EEPROM programmed data.