Speed Control Methods
Setting
Description
Front Panel Speed Control
using J1939 TSC1
The controller can instruct the ECM of an electronic engine to adjust its
speed by broadcasting the TSC1 command.
Refer to the J1939 Reference Manual for more information.
Front Panel Speed Control
using Switched Outputs
The controller can instruct the ECM of an electronic engine to adjust its
speed by using switched outputs on the controller set to RPM Increment
and RPM Decrement to interface with digital inputs on the ECM. When the
speed is changed, the corresponding switched output will be on for
1 second each time increment or decrement is pressed.
See the rest of this section for more information.
Aux 4 Speed Control
The Auxiliary Sensor 4 is used to determine the setpoint speed. The speed
is adjusted with the TSC1 J1939 command.
Refer to the J1939 Reference Manual for more information.
WARNING
SWITCHED OUTPUTS HAVE A FLOATING VOLTAGE OF APPROXIMATELY 8 V WHEN OFF. IF
USING THE OUTPUTS FOR DIGITAL LOGIC, IT WILL BE NECESSARY TO PUT A PULL-DOWN
RESISTOR (2.2 K
Ω, 1 WATT) FROM THE OUTPUT TO GROUND TO ENSURE A LOW LOGIC
LEVEL WHEN OUTPUT IS OFF.
AVERTISSEMENT
LES SORTIES COMMUTEES PRESENTENT UNE TENSION FLOTTANTE D'ENVIRON 8 V
LORSQU'ELLES SONT OFF (INACTIVES). SI VOUS SOUHAITEZ UTILISER LES SORTIES
COMME SIGNAUX LOGIQUES NUMERIQUES, IL FAUT INSTALLER UNE RESISTANCE PULL-
DOWN (2,2 K
Ω, 1 W) ENTRE LA SORTIE CONCERNEE ET LA MASSE, POUR ASSURER UN
NIVEAU LOGIQUE BAS QUAND LA SORTIE EST OFF.
Front Panel Speed Control Using the Switched Outputs
Settings
Name
Parent Menu
Range
Default
Description
Speed
Control
Enable
RapidCore only.
Engine Speed
menu.
Enable
Disable
Disable
(Programmable from RapidCore
Configurator Software only)
Enables or disables front panel speed
control.
RPM
Display
Sensors >
Engine Speed
Blank
AC Hertz
Aux Sensor 1
Aux Sensor 2
AC Hertz
Parameter to display when adjusting
speed from front panel. This is used to
provide operator feedback in the case
that the engine RPM affects another
parameter such as AC Frequency or an
Auxiliary Sensor (example: flow rate of
pump).
!
!
Summary of Contents for DYNAGEN TOUGH Series TE410
Page 1: ...TOUGH SeriesTM TE410 User Manual ...
Page 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Page 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Page 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...