DynaGen
TM
TOUGH Series
TM
TE410 - EN
User Manual
46
9M02-9249-A001-EN
Revision A
5
Settings
The following section relates to settings that can be changed to alter the way the controller performs its
functions. Read and review these sections carefully to ensure your settings are set correctly for your engine.
5.1
Operator Setup
The following settings are used to change the way the user interacts with the controller. They are not password
protected and can be changed by anyone from the front panel.
Name
Range
Default Setting
Description
Lamp Test
-----
-----
Performs a lamp test on the LEDs when
selected.
Display > LCD
Reverse
-----
-----
Reverses the white and black pixels when
selected.
Display > LCD
Contrast
5 ~ 95%
50%
Changes the contrast of the LCD.
Display > Page
Scroll
1 ~ 10 s
5 s
Amount of time between each auto scroll of
the parameter pages.
Display > Message
Pop-Up
1 ~ 10 s
2 s
Amount of time each message is displayed
on the screen before displaying next
message in the buffer.
Display > DPF/DEF
Display Time
0 ~ 10 s
2 s
See DPF/DEF aftertreatment in the J1939
Reference Manual
for more information.
Display > LCD
Backlight Timeout
10 ~ 600 s
600 s
Amount of time the LCD Backlight stays on
after button activity stops.
Display > Default
Application Menu
Tank Level /
Float Application
Wind Machine
Application
Tank Level /
Float Application
(configurable using RapidCore software only)
Sets the front panel application menu. The
application menu is the first menu listed in
the menu system and is where end users go
to configure the controller.
Display > Default
Display Page
Display Page 1
Display Page 2
Transducer Tank
Page
Display Page 1
(configurable using RapidCore software only)
Set the page in Run Mode that will be
displayed after the
‘no button presses
timeout
’ is activated.
Display > Display
Page 1
Parameters >
Display for Line 1
Display for Line 2
Display for Line 3
Display for Line 4
•
Blank Line
•
Engine Speed
•
Battery
•
AC Frequency
•
Current Run
Time
Page 1
Engine Speed
Battery
AC Frequency
Current Run
Time
(configurable using RapidCore software only)
Two of the Run Mode scrolling pages can be
customized. Up to four parameters (lines)
per page can be shown.
If
“Blank Line” is set for two consecutive
lines, then those two lines are removed and
all sequent lines are moved up. If only one
Summary of Contents for DYNAGEN TOUGH Series TE410
Page 1: ...TOUGH SeriesTM TE410 User Manual ...
Page 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Page 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Page 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...