< Work procedure 1-1>
1 / 7
<Remedy>
_Check that the Engagement/Disengagement Cam of the Registration Slave Roller rotates
smoothly. (A loosened screw, a misaligned cam, etc.) [A],
_Check that the bearing at the Engagement/Disengagement Arm of the Registration Slave Roller
is rotating smoothly. [B],
_Check that the Drive Belt of the Registration Drive Roller rotates smoothly. [C],
_Check the connectors between the Registration Motor (M26) and the Registration/Duplexing
Driver PCB. [D]
<Detailed work procedure>
1) Open the Front Left Cover and the Front Right Cover.
2) Pull out the Fixing Feed Unit.
3) Open the duplex feed unit.