45
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© 2001-2008 Calix. All Rights Reserved.
Preparing the Cabinet for Installation
Complete the following preparations before installing the cabinet.
ALERT!
Isolation mat usage is mandatory for all installations. Failure to use
the isolation mat can accelerate cabinet corrosion and may void the Calix
cabinet warranty.
To prepare the cabinet for installation
1.
Open the front, rear, and splice compartment doors.
2.
Open the front and rear battery compartment doors.
3.
In the fiber splice compartment, remove the AC duct cover (two panels) as follows:
a.
Loosen (but do not remove) the mounting screws securing the duct cover panels to
the fixture.
b.
Slide the upper panel sideways to align its two keyholes with the two mounting
screws. When aligned, pull the panel away from the fixture.
c.
Slide the lower panel sideways to align its two keyholes with the two mounting
screws. When aligned, pull the panel away from the fixture.
4.
From the battery compartment, remove the box containing the installation kit and set it
aside for use during installation.
5.
From the rear compartment, remove the isolation mat and set it nearby for use during
installation.
6.
Close the front and rear compartment doors. Leave the splice and battery compartment
doors open.
7.
Remove the six bolts securing the cabinet to the pallet. The bolts are located at the
corners of the cabinet (two in each splice compartment) plus two in the battery