background image

ME-1015 

 

Enclosure for Networked Access Controllers 

Installation Manual 

1.

 

Introduction 

The ME-1015 power management enclosure is a lockable metal 

cabinet for indoor use supporting Rosslare’s AC-215x, AC-225x, and 

AC-425x, networked control panels. 
The ME-1015 enclosure has a Universal Power Socket (UPS) with a 

C14 standard plug for the VAC switcher power supply, as well as an 

audio speaker sounder for chime, bell, and siren. 
The ME-1015 has a VDC power management board with charger for 

a 12 V / 7 Ah lead acid battery, and output power supply. 
The unit has a LED illumination bar that is connected to the 

controller boards and lights when the enclosure door is open. The 

illumination bar includes a green power status LED and a tamper 

switch at the front of the enclosure. With the built-in pre-wired 

tamper switch, an event is generated and sent to the AxTraxNG™ 

server any time the main cover is opened. 

Figure 1: ME-1015 Door Open and Locked 

 

 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics – Power 

Enclosure  

Input: 100 to 240 VAC, 1.6 A, 50–60 Hz, 

switch mode power management board 
C13 power cord 
Switching Power Supply Output: 15 VDC, 

4 A 

PM-10 PCBA Input Power 

15 VDC, 2 A, regulated power 

management board 

Backup Battery 

12 V sealed lead acid (SLA) up to 7 Ah 
Automatic Charging Circuit @ 300mA 
Power switches to UPS Mode when mains 

fail 

PM-10 PCBA Output Power 

Channel 1: 13.8 VDC @ 2 A for 

panel/readers 
Channel 2: 13.8 VDC @ 2 A for locks 
Channels are physically isolated and 

fused with PTC resettable fuse 

LED Indicators 

1 red LED for each power output, lights 

when the power is active 

2.2

 

Electrical Characteristics – Others 

Lightbar™ Current Consumption 

10 mA – 10 LED light (white LED) – 0.3 W 

Built-In Speaker 

0.5 Watt – 8 Ohm 

Tamper Switch 

Normally Open (closed when cover is 

closed) 
2-Wires – Built in to the light bar 

Power Logic States 

Main Power – Restored 
Main Power – Failed 
UPS Battery – No UPS battery detected 
UPS Battery – UPS mode started 
UPS Battery – UPS mode ended 
UPS Battery – UPS low battery (30%) 

2.3

 

Environmental Characteristics 

Operating Environment 

Indoor 

Operating Temp. Range 

0°C to 50°C (32°F to 122°F) 

Operating Humidity Range 

0 to 85% (non-condensing) 

2.4

 

Physical Characteristics 

Enclosure Dimensions 

(H x W x D) 

364 x 264 x 87.4 mm 

(14.3 x 10.4 x 3.4 in.) 

Enclosure Weight* 

3.4 kg (7.5 lb) 

*  For weight purposes, the ME-1015 enclosure includes the metal box, AC 

input, DC output and LED bar. 

Reviews: