Rear Compartment
The rear compartment provides 94 inches of vertical rack space (54 RU). The rear
compartment is split into two equipment bays (47 inches/27 RU per bay) and houses no
standard equipment, leaving the full 54 RU of rack space available for optional or third-party
equipment. The swing frame rack design allows for easy access to the backside of mounted
equipment.
ODC-3000 Rear
Splice Compartments
The ODC-3000 cabinet is equipped with two standard splice compartments: a fiber splice
chamber (located on the right side of the cabinet when viewed from the front) and a copper
splice chamber (located on the left side of the cabinet when viewed from the front). The
fiber splice compartment is equipped with a standard 23-inch rack and houses the AC load
center, main ground bar, and provides cable entry locations for fiber plant.
The copper splice compartment provides cable entry locations for copper plant and houses
the copper line protection, which consists of up to four rack-mounted protection frames,
each holding up to 10 modular 50-pair protection blocks. The modular design of the copper
line protection system allows for incremental expansion if required.