23 June 2015
Version 1.7
Page 25-5
25.3.
Calibrating milk meter
Steps
To calibrate the milk meter, follow the steps in
STEP ACTION
1.
Switch the milking box in
SERVICE
operation mode.
2.
Hang a steelyard.
3.
Set the steelyard at 0.
4.
Hang a bucket between milk meter and receiver jar.
5.
Milk at least 3 cows manually.
Yield per cow in the
MILK BOX STATE
part in the
BRI
main
screen > 5 kg.
6.
Weigh the milk of each cow in the milk bucket.
The value may not deviate more than 2% yield in kg from
the value that is displayed in the
MILK BOX STATE
part in the
BRI
main screen.
7.
Calculate the new calibration value with the next formular:
Milk meter cal. (0.105) x steelyard value (bucket)
----------------------------------------------------------
Measured value
8.
Add all calculated calibration values that you calculated in step
divide this by the number of milked cows.
9.
Open the
SETTINGS
tab of the
SERVICE
window in
BRI
.
10.
Press the
MILK SETTINGS
).
) will be displayed.