23 June 2015
Version 1.7
Page 22-13
STEP ACTION
14.
Tighten the pump housing with the screw nuts.
NOTE
: first tighten the rear screw nut and then the front one.
Pay close attention that the gasket (1) (see
) is
positioned straight between pump housing and milk pump.
Beware sharp edges.
Figure 22-20 Gasket
15.
Fix the rubber socket again.
16.
Fix the pump housing with the clamp.
17.
Replace the cover at the milk pump.
18.
Fix the cover with the bolts at the upper and lower side.
19.
Switch on the
F4
button in the main control cabinet.
Scheme 22-3 Replacing wearing parts milk pump