Page
Motor slip frequency configuration.................................................... 162
Motor parameter auto-tuning............................................................. 163
V/f curve selection............................................................................. 166
User-defined V/f curve configuration................................................. 167
Slip compensation factor configuration............................................. 169
Torque boost setting.......................................................................... 170
Optimization functions for V/f control............................................... 173
13
13.1
Display of LED Characters................................................................. 175
13.2
13.3
Warning Code.................................................................................... 175
13.4
13.4.1 Error 1 (OC-1): Overcurrent at Constant Speed................................ 176
13.4.2 Error 2 (OC-2): Overcurrent during Acceleration............................... 176
13.4.3 Error 3 (OC-3): Overcurrent during Deceleration.............................. 176
13.4.4 Error 4 (OE-1): Overvoltage at Constant Speed................................ 177
13.4.5 Error 5 (OE-2): Overvoltage during Acceleration............................... 177
13.4.6 Error 6 (OE-3): Overvoltage during Deceleration............................... 177
13.4.7 Error 7 (OE-4): Overvoltage during Stop........................................... 178
13.4.8 Error 8 (UE-1): Undervoltage during Run........................................... 178
13.4.9 Error 9 (SC): Surge Current or Short Circuit..................................... 178
13.4.10 Error 10 (IPH.L): Input Phase Loss.................................................... 178
13.4.11 Error 11 (OPH.L): Output Phase Loss............................................... 178
13.4.12 Error 12 (ESS-): Soft Start Error........................................................ 179
13.4.13 Error 20 (OL-1): Converter Overload.................................................. 179
13.4.14 Error 21 (OH): Converter over Temperature...................................... 179
13.4.15 Error 23 (FF): Fan Failure................................................................... 180
13.4.16 Error 24 (Pdr): Pump Dry ................................................................. 180
13.4.17 Error 25 (CoL-): Command Value Lost ............................................... 180
13.4.18 Error 30 (OL-2): Motor Overload........................................................ 180
13.4.19 Error 31 (Ot): Motor over Temperature............................................. 181
13.4.20 Error 32 (t-Er): Motor Parameter Tuning Error................................... 181
13.4.21 Error 38 (AibE): Analog Input Broken Wire Detection........................ 181
13.4.22 Error 39 (EPS-): DC_IN Power Supply Error....................................... 181
13.4.23 Error 40 (dir1): Forward Running Lock Error..................................... 181
13.4.24 Error 41 (dir2): Reverse Running Lock Error..................................... 182
VFC 3210
Bosch Rexroth AG
Table of Contents
DOK-RCON04-VFC3210****-IT01-EN-P