E2: Output terminal parameters
Code
Name
Setting range
Default
Min.
Attri.
E2.15 Relay 1 output selection
0...25
1
–
Stop
E2.20
DO1/relay1 output values from
extension card fieldbus commu-
nication
Bit8:
0 (Tb_Ta is opened)
1 (Tb_Ta is closed)
0
–
Run
E2.26 AO1 output setting
0: Output frequency
1: Setting frequency
2: Output current
4: Output voltage
5: Output power
6: AI1 analog input
12: Parameter setting from com-
munication
②
0
–
Run
E2.27 AO1 gain
0.00...10.00
1.00
0.01
Run
E2.28
AO1 value in percentage from
extension card fieldbus commu-
nication
0.00...100.00 %
0.00
0.01
Run
E2.40 Rated voltage
1P 200...240 VAC
220
1
Stop
3P 380...480 VAC
380
E2.50 Output curve 1 minimum
0.0 %...[E2.52]
0.0
0.1
Run
E2.51 Output curve 1 minimum value 0.00...100.00 %
0.00
0.01
Run
E2.52 Output curve 1 maximum
[E2.50]...100.0 %
100.0
0.1
Run
E2.53 Output curve 1 maximum value 0.00...100.00 %
100.00 0.01
Run
E2.70 Frequency detection width
0.00...400.00 Hz
2.50
0.01
Run
E2.71 Frequency detection level FDT1 0.01...400.00 Hz
50.00
0.01
Run
E2.72
Frequency detection level
FDT1 width
0.01...[E2.71] Hz
1.00
0.01
Run
E2.73 Frequency detection level FDT2 0.01...400.00 Hz
25.00
0.01
Run
E2.74
Frequency detection level
FDT2 width
0.01...[E2.73] Hz
1.00
0.01
Run
E2.80 Counter middle value
0...[E2.81]
0
1
Run
E2.81 Counter target value
[E2.80]...9,999
0
1
Run
Setting range of E2.15:
0: Converter ready
1: Converter running
2: Converter DC-braking
Bosch Rexroth AG
Appendix
VFC 3210
240/253
DOK-RCON04-VFC3210****-IT01-EN-P