E3: Multi-speed and simple PLC parameters
Code
Name
Setting range
Default Min. Attri.
E3.00 Simple PLC running mode
0: Inactive
1: Stop after selected cycle
2: Continuously cycling
3: Run last stage after selected cycle
0
–
Stop
E3.01 Simple PLC time multiplier 1...60
1
1
Stop
E3.02 Simple PLC cycle number 1...1,000
1
1
Stop
E3.10 Acceleration time 2
0.1...6,000.0 s
10.0
0.1
Run
E3.11 Deceleration time 2
0.1...6,000.0 s
10.0
0.1
Run
E3.12 Acceleration time 3
0.1...6,000.0 s
10.0
0.1
Run
E3.13 Deceleration time 3
0.1...6,000.0 s
10.0
0.1
Run
E3.14 Acceleration time 4
0.1...6,000.0 s
10.0
0.1
Run
E3.15 Deceleration time 4
0.1...6,000.0 s
10.0
0.1
Run
E3.16 Acceleration time 5
0.1...6,000.0 s
10.0
0.1
Run
E3.17 Deceleration time 5
0.1...6,000.0 s
10.0
0.1
Run
E3.18 Acceleration time 6
0.1...6,000.0 s
10.0
0.1
Run
E3.19 Deceleration time 6
0.1...6,000.0 s
10.0
0.1
Run
E3.20 Acceleration time 7
0.1...6,000.0 s
10.0
0.1
Run
E3.21 Deceleration time 7
0.1...6,000.0 s
10.0
0.1
Run
E3.22 Acceleration time 8
0.1...6,000.0 s
10.0
0.1
Run
E3.23 Deceleration time 8
0.1...6,000.0 s
10.0
0.1
Run
E3.40 Multi-speed frequency 1
0.00...[E0.09] Hz
0.00
0.01 Run
E3.41 Multi-speed frequency 2
0.00...[E0.09] Hz
0.00
0.01 Run
E3.42 Multi-speed frequency 3
0.00...[E0.09] Hz
0.00
0.01 Run
E3.43 Multi-speed frequency 4
0.00...[E0.09] Hz
0.00
0.01 Run
E3.44 Multi-speed frequency 5
0.00...[E0.09] Hz
0.00
0.01 Run
E3.45 Multi-speed frequency 6
0.00...[E0.09] Hz
0.00
0.01 Run
E3.46 Multi-speed frequency 7
0.00...[E0.09] Hz
0.00
0.01 Run
E3.59 Stage 0 frequency source
0: Digital setting frequency
1: AI1 analog input
5: Communication
6: Panel potentiometer
7: Digital input up/down command
0
–
Stop
Bosch Rexroth AG
Appendix
VFC 3210
242/253
DOK-RCON04-VFC3210****-IT01-EN-P