7.5.3.14
PLC output signal messages
MID 0500
Subscription Output signal change
MID 0501
Upload Output signal change
Table 7–45:
MID 0411 revision 001
Parameter
Comments
Bytes
AutoDisable status
Status of the automatic disable on option
Disable when OK/NOK
number is reached
at
OK/NOK counter
Possible values:
– 00: not selected
– 01: selected
The value consists of two ASCII characters.
ID
-
Value range
00 – 01
Presetting
-
Example:
AutoDisable
status
Not set
Value
00
2
OK/NOK counter value
Fixed value 00
Fixed value
00
2
Data length revision 001
4
Sent by:
superordinate computer
As a consequence of this message, the superior computer is informed about every change in the configurable output
signals at the OP PLC module by means of a message (upload change in output signals,
). After confirmed
logon (command accepted,
), the tightening controller moreover sends a message (upload change in the
output signals,
) with the current assignment of the output signals to the superior computer.
Note: -
Revision:
001
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
86
Activation for output signal change already available
Sent by:
Tightening controller
The assignment of the output signals at the OP PLC module has changed.
Note: -
Revision:
Data field:
Number of signals, 8 bytes or 16 bytes
Possible response
MID
Error no. Comment
Acknowledgement Upload output signal
change
0502
–