88
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0005
Command accepted
7.5.3.4
Tightening program messages
MID 0010
Tightening program numbers upload request
MID 0011
Tightening program numbers upload response
MID
0018
Error no.
02
Data field value
001802
Sent by:
Tightening controller
With this message, the tightening controller confirms that the last request sent by the superior computer has been
accepted.
Note:
-
Revision:
Data field:
Data 4 bytes
Possible response: none
Table 7–11:
MID 0005 revision 1
Parameter
Comments
Bytes
MID
MID of the accepted request
ID
-
Value range
0000 – 9999
Presetting
-
Example:
MID
18
Value
0018
4
Data length revision 001
4
Sent by:
superordinate computer
Request for all available tightening program numbers
Note:
-
Revision:
001
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Tightening program numbers upload
response
0011
–
All valid tightening program numbers in the
tightening controller are transferred after this
command is output.
Sent by:
Tightening controller
Transfer of all available tightening program numbers from the tightening controller.
Note:
Only program numbers 0 … 99 that are available are uploaded.
Revision:
Data field:
total data length = (1 + number of tightening programs) x 3 bytes
Possible response: none