3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 127
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Job number
Number of the selected OK/NOK counter
The job number consists of two ASCII characters.
ID
-
Value range
01 – 99
Presetting
-
Example:
Job number
2
Value
02
2
Tightening program number
Number of the current tightening program.
The value consists of three ASCII characters.
ID
-
Value range
000 – 999
Presetting
-
Example:
Tightening
program number
5
Value
005
3
OK counter limit
OK counter presetting
The value consists of four ASCII characters.
ID
-
Value range
0000 – 9999
Presetting
-
Example:
OK counter limit
12
Value
0012
4
OK counter value
– Start as a single channel: Actual value of the OK counter
– Start in an application: Fixed value 1
The value consists of four ASCII characters.
ID
-
Value range
0000 – 9999
Presetting
-
Example:
OK counter value
4
Value
0004
4
OK/NOK counter status
Status of the OK/NOK counter.
– 0: if not 1 or 2
– 1: Ch x.y CntOK = 1
– 2: OK/NOK counter not used (not configured)
The value consists of one ASCII character.
ID
-
Value range
0 – 2
Presetting
-
Example:
OK/NOK counter
status
OK/NOK counter not used
Value
2
1
Table 7–36:
MID 0061 revision 999
Parameter
Comments
Bytes