160
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
7.5.3.18
Keep alive messages
MID 9999
Keep alive message
Example
2
In the tightening program no. 1, the speed in the 1. tightening step (start step = step number 1, 1.
tightening step = step number. 2) is set to -250 min-1 and the 1. target function is set to torque with a
target value of 3.5 Nm.
Data field 1 Data field 2
| |
--------------------------------------- --------------------------------------
001 002 02052 004 02 101 0002 -250 05100 003 03 001 0002 3.5
| | | | | | | | | | | | | |
| | | | | | | | | | | | | Data value
| | | | | | | | | | | | Step number
| | | | | | | | | | | Unit
| | | | | | | | | | Data type
| | | | | | | | | Length
| | | | | | | | PID
| | | | | | | Data value
| | | | | | Step number
| | | | | Unit
| | |
| Data type
| | | Length
|
| PID
| Number of data fields
Tightening program number
Sent by:
superordinate computer
The superior computer sends a keep alive message to the tightening controller. The tightening controller returns the
received message to the superior computer.
A communication timeout of 15 s (can be parameterized by the BS) applies to the tightening controller, i. e. if no
message is exchanged between the superior computer and the tightening controller within 15 s, the tightening
controller will believe that the connection has been disrupted and disconnect it.
Note:
We recommend sending a message (keep alive or other) to the tightening controller at the latest every 10 seconds
to avoid undesired connection disruptions (with high latency times with TCP/IP).
Revision:
001
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Keep alive message MID 9999 (mirrored
from the tightening controller)
–