140
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0075
Acknowledgement System error in tightening controller acknowledged
MID 0076
System error status
MID 0076 revision 001
Sent by:
superordinate computer
Acknowledgement for MID 0074
Note: -
Revision:
001
Data field:
is empty, 0 bytes
Possible response:
none
Sent by:
Tightening controller
The system error status is sent after a subscription for system errors from the tightening controller has been accepted.
Note:
The system error status informs the superior computer that a system error is currently active in the connected
controller. Exactly one system error status message is sent for each active system error in the connected controller.
Revision:
Data field:
Data 36 bytes
Possible response
MID
Error no. Comment
System error status acknowledgement
0077
–
Table 7–42:
MID 0076 revision 001
Parameter
Comments
Bytes
System error status
– 0: No system error active
– 1: A system error is currently active
The value consists of one ASCII character.
ID
01
2
Value range
0 – 1
Presetting
-
Example:
System error
status
A system error is active
Value
0
1
Error number
The value consists of four ASCII characters.
ID
02
2
Value range
0000 – 9999
Presetting
-
Example:
Error number
105
Value
0105
4
Controller ready status
Always NOK (=0), as no differentiation is made between controller and
tool.
The value consists of one ASCII character.
ID
03
2
Fixed value
0
1