3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 135
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Tapping status of self-tapping
bolts
Tapping status of self-tapping bolts: not supported.
The value consists of one ASCII character.
ID
15
2
Fixed value
0
1
Placeholder value
The value consists of one ASCII character.
ID
16
2
Fixed value
0
1
Placeholder value
The value consists of one ASCII character.
ID
17
2
Fixed value
0
1
Tightening error status
Error bits indicate errors in the tightening system and are generated from
the following bits in the quality code:
– bit 1 (AngTotH): The total angle is above the defined tolerance
window.
– bit 2 (AngTotL): The total angle is below the defined tolerance
window.
– Bit 3 (TorqH): The torque is above the defined tolerance window.
– bit 4 (AnglH): The angle is above the defined tolerance window.
– Bit 14 ((C)Cw=0): CCw or Cw deactivated during the tightening.
– bit 15 (TorqL): The torque is below the defined tolerance window.
– bit 18 (Start-up test): Start-up test NOK
– bit 21 (TimeH): The time is above the defined tolerance window.
– bit 23 (En=0): Enable during tightening deactivated.
The value consists of ten ASCII characters.
ID
18
2
Value range
0000000000 – 9999999999
Presetting
-
Example:
Tightening error
status
AngTotH
Value
0000000001
10
Torque (T)
The value is multiplied by 100 and transferred as a whole number
(rounded to 2 decimals).
The value consists of six ASCII characters.
ID
19
2
Value range
000000 – 999999
Presetting
-
Example:
Torque (T)
20.11
Value
002011
6
Angle (A)
The value is output in degrees.
The value consists of five ASCII characters.
ID
20
2
Value range
00000 – 99999
Presetting
-
Example:
Angle (A)
60
Value
00060
5
Total angle (AT)
Total angle (AT): not supported
The value consists of five ASCII characters.
ID
21
2
Fixed value
00000
5
Table 7–38:
MID 0065 revision 002
Parameter
Comments
Bytes