6.1
PLC signals
The default delivery of the Nexo cordless Wi-Fi nutrunner includes a PLC assignment table that has
already been configured.
The PLC assignment table defines the assignment of the control signals to the physical interfaces of the
Nexo cordless Wi-Fi nutrunner. These control signals can be used to integrate the tightening controller
into a system sequence. The following numbers of inputs and outputs are available on the interfaces:
.
The configuration of the PLC assignment table can be adjusted to customer requirements using the
NEXO-OS operating system; see menu item
Settings
.
6.2
Description of all PLC signals
The sections below provide a description of all PLC signals in alphabetic order.
6.2.1
Input signals
Overview of PLC input signals
Table 6–1:
Number of inputs and outputs
PLC module
Inputs
Outputs
tool
- Nutrunner
16
0
oprtcl
- Rexroth Open Protocol
48
16
vwXml
- VW-XML
40
56
Signal
Function
Description
AbortVin
3)
Abort Vehicle Identification Number Cancel current order
ActEn
Active Enable
Enables a single tightening process
ActScan
1
)
1
Supported as of Nexo firmware version 1100
Active Scanner
Enables a single scan process
AppIn0-15
Application In Bit 0-15
Application-specific input signal
Ccw
Counterclockwise
Loosen
CcwIgnore
Counter clock wise ignore
Ignores the Ccw switch
CwIgnore
Clock wise ignore
Ignores the Cw switch
CcwLock
Counter clock wise lock
Disables the loosening function
Cw
Clockwise
Starts tightening in clockwise direction
CwLock
Clock wise lock
Disables the starting function
CntRes
Counter Reset
Resets the counter value
CntSel0-7
Counter Select Bit 0-7
Selects the counter value
DisRp
Disable Report
Suppresses the results output
DisRpFtp
Disable Report Ftp
Suppresses the results output via FTP
DisScan
3)
Disable scanner
Block the scanner
En
Enable
Enables
JobAbort
1)
Job Abort
Aborts a job
JobEnable
1)
Job Enable
Activates a job
JobResRs
1)
Job Reset Result
Resets a job result
JobStart
1)
Job Start
Starts a job
Job0-7
1)
Job 0-7
Job selection
ManOP
2
)
Manual Operation Mode
Change-over manual mode
NokAc
Not OK acknowledge
NOK acknowledge
Prog0-7
Program 0-7
Program selection
ResF
Reset Fault
Resets a system error
ResRs
Reset Result
Resets a result
WasByPass
3)
WAS Bypass
Order nutrunner via PLC\LisWAS is ignored