86
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0002 revision 002
MID 0002 revision 003
Example:
Using the values from the example above, the value of the data field for revision 2 would be as follows:
010003020403tightening channel
04BRC
Table 7–8:
MID 002 revision 002
Parameter
Comments
Bytes
This revision includes the information from revision 001 and the following additional information:
Manufacturer code
The value consists of three ASCII characters.
ID
04
2
Fixed value
BRC
3
Data length revision 002 (= data length revision 001 + data length revision 002)
42
Table 7–9:
MID 002 revision 003
Parameter
Comments
Bytes
This revision includes the information from revision 002 and the following additional information:
Open Protocol version
The Open Protocol version is transferred.
The value consists of 19 ASCII characters.
ID
05
2
Value range
0x20 – 0x7F
Presetting
-
Example:
Open Protocol version
7.0 version 34
Value
7.0 version 34
19
Software version
The version transferred is the firmware version of the nutrunner.
The value consists of 19 ASCII characters.
ID
06
Value range
0x20 – 0x7F
Presetting
-
Example:
Software version
NxFw-V1000
Value
NxFw1000
19
Tool software version
The value consists of 19 ASCII characters. Only space characters are
transmitted.
ID
07
2
Value range
0x20 – 0x7F
Presetting
-
Example:
Software version
-
Value
19
Data length revision 003 (= data length revision 002 + data length revision 003)
105