104
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0037
Cancel job info subscription
MID 0038
Select job number
MID 0038 revision 001
MID 0038 revision 002
Sent by:
superordinate computer
Reset the subscription for the job info.
Note:
-
Revision:
(supported by Rexroth OP)
Data field:
is empty, 0 bytes
Possible response:
MID
Error no. Comment
Command accepted
0005
-
Command error
0004
98
Activation for job info not available
Sent by:
superordinate computer
This command can be used to select the job number.
Note:
In the PLC assignment table, the
Job <n>
signal must be applied to the OP module.
Revision:
(supported by Rexroth OP)
Data field:
Possible response:
MID
Error no. Comment
Command accepted
0005
-
Command error
0004
20
Job cannot be specified.
Table 7–23:
MID 0038 revision 001
Parameter
Comments
Bytes
Job number
The value consists of two ASCII characters.
ID
-
Value range
00 – 99
Presetting
-
Example:
Job number
1
Value
01
2
Data length revision 001
2
Table 7–24:
MID 0038 revision 002
Parameter
Comments
Bytes
Job number
The value consists of four ASCII characters.
ID
-
Value range
0000 – 0255
Presetting
-
Example:
Job number
1
Value
0001
4
Data length revision 002
4
Data 2 bytes (revision 001), 4 bytes (revision 002)