3 608 870 A47
Tightening Technology |
Bosch Rexroth AG
63
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
6.2.2
Output signals
Overview of PLC output signals
Signal
Function
Description
Ack0-7
Acknowledge 0-7
Acknowledges program selection
ActEnAck
Active enable acknowledge
Acknowledgement scan process active
ActScanAck
1
)
1 Supported as of Nexo firmware version 1100
Active scanner acknowledge
Acknowledges enabling of a single scan process
AnglH
Angle too high
Angle too high
AnglL
Angle too low
Angle too low
AppOut0-15
Application Out Bit 0-15
Application-specific output signal
BattOk
Battery OK
State of the battery pack slide-in module
BattOff
Battery OFF
Battery pack slide-in module not inserted
CntSelAck0-7
Counter Select acknowledge Bit 0-7 Acknowledge counter set selection
CcwAck
Counter clock wise acknowledge
Acknowledges a loosening operation
CntCanceled
Counter canceled
Counter set canceled
CcwLockAck
Counter clock wise lock
acknowledge:
Acknowledges that loosening is disabled
CCwSel
Counterclockwise Select
Loosening program selected at nutrunner
CwAck
Clock wise acknowledge
Acknowledges a start
CwLockAck
Clock wise lock acknowledge
Acknowledges that start is disabled
CntNOK
Counter NOK
NOK counter has reached default value
CntOK
Counter OK
OK counter has reached default value
CyCmp
Cycle Complete
Process end
CheckTool
Check the tool
Nutrunner test interval reached
EnAck
Enable acknowledge
Acknowledges enabling
EnScanAck
1)
Enable scanner acknowledge
Acknowledgement release scanner
FtpF
Ftp Fault
Results transfer error
InCy
In Cycle
Tightening program active
InCyCcw
In Cycle Counterclockwise
Loosening is active
JobAck0-7
1)
Job acknowledge 0-7
Acknowledges the selected job
JobCyCmp
1)
Job Cycle Complete
The job is finished
JobIncy
1)
Job In Cycle
The job is active
JobNOK
1)
Job Not OK
The job result is not okay
JobOK
1)
Job OK
The job result is okay
JobRdy
1)
Job ready
The job is ready
ManOpAck
2
)
2 Supported as of Nexo firmware version 1300
Manual Operating Mode
acknowledge
Manual mode acknowledgment
NF
No Fault
Nutrunner without system errors
NOK
Not OK
Result not OK
OK
OK
Results OK
RC0-4
1)
Rework Code Bit 0-4
Rework code bit 0-4
Rdy
Ready
Nutrunner ready for operation
ScanRdy
1)
Scanner ready
Scanner ready
ScanRxID
1)
Scanner read ID
Barcode read
StartBn
Start button
State of the start switch
TimeH
Time too high
Time too high
TorqH
Torque too high
Torque too high
TorqL
Torque too low
Torque too low