100
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Repeat job
Repeat job:
– 0: No
– 1: Yes
The value consists of one ASCII character.
ID
09
2
Value range
0 – 1
Presetting
-
Value
1
Loosen options
– 0: At least one of the loosen program lock options
after OK result
,
after NOK result
and/or
before start processing
is not active in all
program steps. (So there is a possibility to loosen in the job)
– 1: All of the loosen program lock options (
after OK result
,
after NOK
result
,
before start processing
) are active
– 2: In all program steps, the only deactivated loosen program lock option
is
after NOK result
The value consists of one ASCII character.
ID
10
2
Value range
0 – 2
Presetting
-
Example:
Allow loosening
Release
Value
0
1
Reserved
Reserved: not supported
The value consists of one ASCII character.
ID
11
2
Fixed value
0
1
Tightening programs number
Number of tightening programs defined in the job.
The value consists of two ASCII characters.
ID
12
2
Value range
00 – 99
Presetting
-
Example:
Number
3
Value
03
2
List of tightening programs
List of N tightening programs with respective parameters. Field separator
":", parameter end ";"
ChannelID:ProgNr:AutoValue:BatchSize;
– ChannelID: two ASCII characters, value range 00 - 99
– ProgNr: three ASCII characters, value range 000 - 999
– AutoValue: one ASCII character, value range 0 - 1
– BatchSize: two ASCII characters, value range 00 - 99
ID
13
2
Value range
-
Presetting
-
Example:
List
aa:bbb:c:dd;aa:bbb:c:dd;
Value
01:005:0:03;
12
Data length revision 002
73 +
N x 12
Table 7–20:
MID 0033 Revision 002
Parameter
Comments
Bytes