3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 229
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Interface
– TCP/IP port A (control data)
Selection of the desired TCP/IP port for data exchange
with the tightening controller (default setting: 4700)
– Keep alive timeout (A)
Indication of the time in which a message from the master PC is to be
received. If no message is received within this time at the port, the
connection will be disconnected (default setting: 8 seconds).
Recommendation: Set the keep alive timeout to a higher value than that
of the master PC.
– TCP/IP port B (process data)
Selection of the desired TCP/IP port for process data and event-
controlled message exchange (default setting: 4710)
– Keep alive timeout (B)
Indication of the time in which the tightening controller must send a
message to the master PC. If no message is received within this time at
the port of the master PC, it will disconnect the connection. (Default
setting: 6 seconds).
Recommendation: Set the keep alive timeout to a lower value than that of
the master PC.
– ACK timeout
Indication of the time in which a confirmation (acknowledge) is to be
received. If no confirmation is received within this time at the port, the
connection will be disconnected (default setting: 3 seconds).
Options
Selection of the default transmission class that is to be used by default for
the transmission of the tightening results data. The transmission class must
be set independently for OK tightening jobs and NOK tightening jobs.
Class 1: All values of the final tightening step without control function
Class 2: Class 1 plus control functions of the final tightening step
Class 3: All values over all levels plus control function over all levels
Class 4: User-defined data scope (setting via SST operating program)
Class 5: Class 3 plus curves (always). The curve transmission is fixedly
defined and cannot be changed. X axis is always the time, Y1 axis is always
the torque and Y2 axis is the angle of turn.
– OK
Selection of transmission class for OK tightening results data (default
setting: 3).
– NOK
Selection of transmission class for NOK tightening results data (default
setting: 5).
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Import
Opens the
Import
dialog. Select the file to be imported.
Export
Exports the current settings to the download area.
Restore defaults
All settings in this tab are reset to the factory setting.
Table 9–74:
VW-XML index card
Element
Description