34
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
3.3
Connection options of the Nexo cordless Wi-Fi nutrunner
Below, various connection options for the use of the Nexo cordless Wi-Fi nutrunner are described:
•
Result storage without radio connection
•
•
•
PLC control and result storage via WLAN
•
Fieldbus control and result storage via WLAN
•
3.3.1
Result storage without radio connection
As of Nexo firmware version 1100, the results data can be stored in the “standard Nexo” format as a *.json
file
on the NX-SD Micro SD card inserted in the nutrunner. Using the NX-A programming adapter, the
results data stored on the NX-SD Micro SD card can be viewed. The NX-SD Micro SD card can also be
accessed using a commercially available Micro SD card reader.
Settings in the NEXO-OS operating system:
•
As of Nexo firmware version 1200: The directory for filing of the results on the NX-SD Micro SD card
can be defined under
Settings
Data
Standard Nexo
NX-SD card
•
Go to the menu
Help
Access to NX-SD card
to access the Micro SD card. The results data are
stored in directory
results
.
D
Fig. 3–8:
Result storage without radio connection
(1)
IPC (industrial computer), laptop or database server
(2)
NX-A programming adapter
Ethernet (TCP/IP)
(2)