216
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-
NX-SD card
Settings
Data
Standard Nexo
NX-SD card)
Under this menu item, the sub-directory for filing of tightening results on the
NX-SD Micro SD card and the contents of the file are defined.
The tightening results are stored on the NX-SD Micro SD card in directory
results
.
HTTP
Settings
Data
Standard Nexo
HTTP
Use this menu item to define the configuration of the HTTP connection for results output.
The Nexo firmware uses the HTTP/1.1 standard.
Table 9–61:
NX-SD card index card
Element
Description
Active
If the check box is activated, the setting is activated.
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Data
Storage
Restore defaults
All settings in this dialog are reset to the factory setting.
Table 9–62:
HTTP index card
Element
Description
Active
Activate the check box to activate data output via HTTP.
If results output is disabled, no more results files will be generated. Results
files which have already been generated and still exist will not be output
before HTTP output has been reactivated.
IP address / DNS
Either directly enter the IP address of the HTTP server or the DNS entry of
the HTTP server.
Port
Selection of the TCP/IP port for data transfer, value range 0 - 65535
Default setting: 8080
Page
Under
Page
, enter the target page of the results files.
User agent
Enter the user agent of the HTTP header.
Default setting: SYS350
1
1
Setting for transmission to Process Quality Manager (PQM). If PQM is applied, the HTTP connection can be used
to transmit the results output data of the tightening controller to the PQM.
Content type
Enter the content type of the HTTP header.
Default setting: application/json
1
Report system errors
As of Nexo firmware version 1400: If this check box is activated, an error file
is sent to the server when a system error occurs/is acknowledged and during
startup.
Default setting: Activated
1
Parameters of the error file see
.
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Data
Storage
Restore defaults
All settings in this dialog are reset to the factory setting.