3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 223
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
File button
Click on the button to display the
File
dialog. In the dialog, the respective parameters for storage of results
data can be edited, deleted or additional memory parameters added.
Table 9–70:
Memory dialog
Element
Description
Output format
Output format for results data.
– Type
Selection of the
json
output format.
– JSON-formatted
Select
yes
to display the results data in a readable JSON format
(including line breaks and spaces). Select
no
to receive an unformatted
JSON data set.
File name
Display on selection of
FTP, NX-SD card
and
File Share
:
Under
file name
the file name for the saved results data file is defined. The
file name can be composed of different parameters. Activate the respective
parameters. Additional user-defined parameters can be added.
File extension
Display on selection of
FTP, NX-SD card
and
File Share
:
Displays the file extension
json
of the saved results data file.
Sub-directory
Display on selection of
FTP, NX-SD card
and
File Share
:
Under
Sub-directory
, a sub-directory is created. The file name of the sub-
directory can be composed of different parameters. Activate the respective
parameters.
Number of files
Display on selection of
NX-SD card
:
On the applied file system of the NX-SD card, sub-directories can only
contain a defined number of files. Due to this restriction, an additional sub-
directory with the current time stamp (
YYYY-MM-DD_hh-mm-ss
) is created
in the configured directory for storage of each results data set. If the
configured number of files is reached, a new sub-directory is automatically
generated with the current time stamp for storage of the results data.
A maximum of 10000 result data records per sub-directory can be stored.
Add
Click
Add
to add a new parameter.
Click
Save
to save the changes or
Cancel
to discard the changed data.
Edit
Click
Edit
to edit a memory parameter. Change the presettings and click
Save
to save the changes or
Cancel
to discard the changed data.
Remove
Click
Remove
to remove a parameter.
Move up / Move down
Click
Move up
or
Move down
to change the order of parameters for
composition of the file name of the sub-directory.
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Restore defaults