3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 109
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0045
Define calibration value request
7.5.3.7
ID code messages
MID 0050
ID code download request
Sent by:
superordinate computer
Calibration value request
Note:
-
Revision:
001
Data field:
Data 11 bytes (revision 001)
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
70
Calibration failed
Table 7–27:
MID 0045 revision 001
Parameter
Comments
Bytes
Unit of the calibration value
– 0: no units
The value consists of one ASCII character.
ID
01
2
Value range
0 – 4
Presetting
-
Fixed value
0
1
Calibration value
The value is multiplied by 1000 and transferred as a whole number
(rounded to 3 decimals).
The value consists of six ASCII characters.
ID
02
2
Value range
500 – 2000
Presetting
-
Example:
Calibration value
1.345
Value
001345
6
Data length revision 001
11
Is still supported, but if a new version is implemented, MID 0150 should be used.
Sent by:
superordinate computer
Is used by the superior computer to send an ID code to the tightening controller.
Note:
OP must be configured as the ID code source.
Revision:
001
Data field:
ID code maximum of 25 ASCII characters (25 bytes). If the ID code is shorter than 25 characters, the
field will be filled with space characters.
Possible responses
MID
Error no. Comment
Command accepted
0005
–
Command error:
0004
08
Entry source for ID code not permissible