7.5.1
Sequence diagrams - examples
Loss of radio communication
Nutrunner
Superordinate system
(OP communication partner)
MID 0001
MID 0060
MID 0018 {Prg. 5}
MID 0019
{OK/ NOKCounter 5, OK = 3, NOK = 0}
MID 0043
1.
{Result ID = 400}
MID0061
{Result ID = 400}
2.
{Result ID = 401}
3.
{Result ID = 402}
TCP connection
establishment via
port 4545
TCP connection
establishment accepted
MID 0001
MID 0042
MID 0064 {Result ID = 0}
MID 0065 {Result ID = 402}
MID 0065 {Result ID = 401}
MID
006
4
{Result
ID
=
401}
Loss of radio
communication
Get last result
Get result delta
TCP connection
establishment accepted
Re-establishing
radio commu-
nication
Tightening process
is taking place
Tightening process
is taking place
Tightening process
is taking place
TCP connection
establishment via
port 4545