3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 117
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Angle (A)
The value is output in degrees.
The value consists of five ASCII characters.
ID
19
2
Value range
00000 – 99999
Presetting
-
Example:
Angle (A)
60
Value
00060
5
Time stamp
Date and time of the tightening.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
20
2
Value range
0 – 9, "-" and ":"
Presetting
-
Example:
Time stamp
1/12/2009:2:43:57 PM
Value
1/12/2009:2:43:57 PM
19
Date/time of the last change
Date and time of the last change in the tightening program settings.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
21
2
Value range
0 – 9, "-" and ":"
Presetting
-
Example:
Date/time of the
change
1/12/2009:2:43:57 PM
Value
1/12/2009:2:43:57 PM
19
OK/NOK counter status
Status of the OK/NOK counter.
– 0: if not 1 or 2
– 1: Ch x.y CntOK = 1
– 2: OK/NOK counter not used (not configured)
The value consists of one ASCII character.
ID
22
2
Value range
0 – 2
Presetting
-
Example:
OK/NOK counter
status
OK/NOK counter not used
Value
2
1
Tightening ID
With an activated OP, consecutive number for each tightening result (for
further information, see
).
The value consists of ten ASCII characters.
ID
23
2
Value range
0000000000 – 9999999999
Presetting
-
Example:
Tightening ID
123456
Value
0000123456
10
Data length revision 001
211
Table 7–31:
MID 0061 revision 001
Parameter
Comments
Bytes