Trailer Crane AHK 30/1400
Setup
02/2008
75
Required
minimum
clearance
Standard voltage, kV
(voltage between phases)
m
When operating in the vicinity of high voltage
lines
to
50
3,0
over 50
to
200
4,5
over 200
to
350
6,0
over 350
to
500
7,5
over 500
to
750
11,0
over 750
to
1000
14,0
During transport operation without load with
lowered boom or mast
to
0,75
1,0
over 0,75 to
50
2,0
over 50
to
345
4,0
over 345
to
750
5,0
over 750
to
1000
6,0
GENERAL COMMENT:
See the table for minimum clearance radius to the
danger zone
Safety distances for hoists and raised loads in the vicinity of overland lines
Pos : 6.14 /Kothes! Networ k/Boeker/Sicherheit/Warnhinweis Abgas e AH K Böc ker @ 26\mod_1166631340367_1.doc @ 287125
WARNING! Danger to life!
Do not inhale the exhaust gases of running internal-combustion engines, as this
can damage your health, cause unconsciousness or even death by suffocation.
Prolonged inhaling of exhaust gases can seriously damage your health!
–
Run the engine only in well ventilated areas!
–
Do not run the engine in closed rooms!