CHAPTER 4: VLAN MANAGEMENT
FIGURE 4-15. PRIVATE VLAN CONFIGURATION
Parameter description:
Delete: To delete a private VLAN entry, check this box. The entry will be deleted during the next apply.
Private VLAN ID: Indicates the ID of this particular private VLAN.
Port Members: A row of check boxes for each port is displayed for each private VLAN ID. To include a port in a Private VLAN, check
the box. To remove or exclude the port from the Private VLAN, make sure the box is unchecked. By default, no ports are members,
and all boxes are unchecked.
Add New Private VLAN: Click to add a new private VLAN ID. An empty row is added to the table, and the private VLAN can be
configured as needed. The allowed range for a private VLAN ID is the same as the switch port number range. Any values outside
this range are not accepted, and a warning message appears. Click “OK” to discard the incorrect entry, or click “Cancel” to return to
the editing and make a correction.
– The Private VLAN is enabled when you click “Apply.”
– The button can be used to undo the addition of new Private VLANs.
Buttons
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values
4.9 PORT ISOLATION
Port Isolation provides for an apparatus and method to isolate ports on layer 2 switches on the same VLAN to restrict traffic flow.
The apparatus comprises a switch having said plurality of ports, each port configured as a protected port or a non-protected port.
An address table memory stores an address table having a destination address and port number pair. A forwarding map generator
generates a forwarding map that is responsive to a destination address of a data packet. The method for isolating ports on a layer
2 switch comprises configuring each of the ports on the layer 2 switch as a protected port or a non-protected port. A destination
address on a data packet is matched with a physical address on said layer 2 switch and a forwarding map is generated for the data
packet based upon the destination address on the data packet. The data packet is then sent to the plurality of ports pursuant to the
forwarding map generated based upon whether the ingress port was configured as a protected or non-protected port.
This page is used for enabling or disabling port isolation on ports in a Private VLAN.A port member of a VLAN can be isolated to
other isolated ports on the same VLAN and Private VLAN.