CHAPTER 12: SNMP
PARAMETER DESCRIPTION
View Name: A string identifying the view name that this entry should belong to. The allowed string length is 1 to 31, and the allowed
content is ASCII characters from 33 to 126.
View Type: Indicates the view type that this entry should belong to. Possible view types are:
Included: An optional flag to indicate that this view subtree should be included.
Excluded: An optional flag to indicate that this view subtree should be excluded.
In general, if a view entry’s view type is “excluded,” there should be another view entry existing with view type as “included” and its
OID subtree should overstep the “excluded” view entry.
OID Subtree: The OID defining the root of the subtree to add to the named view. The allowed OID length is 1 to 128. The allowed string
content is a digital number or asterisk(*).
Buttons
Add New Entry: Click to add a new entry. Specify the name and configure the new entry. Click “Apply.”
Delete: Check to delete the entry. It will be deleted during the next save.
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
12.2.5 ACCESS
This function is used to configure SNMPv3 access. The Entry index keys are Group Name, Security Model and Security level. To
create a new access account, check the <Add new access> button and enter the access information, then check <Apply>. Max Group
Number : 12.
WEB INTERFACE
To display the configure SNMP Access in the web interface:
1. Click SNMP, SNMPv3 and Accesses.
2. Click Add new entry.
3. Specify the SNMP Access parameters.
4. Click Apply.