CHAPTER 12: SNMP
FIGURE 12-9. RMON HISTORY CONFIGURATION
PARAMETER DESCRIPTION
ID: Indicates the index of the entry. The range is from 1 to 65535.
Data Source: Indicates the port ID to be monitored. If in stacking switch, the value must add 1000*(switch ID-1), for example, if the port
is switch 3 port 5, the value is 2005.
Interval: Indicates the interval in seconds for sampling the history statistics data. The range is from 1 to 3600, default value is 1800
seconds.
Buckets: Indicates the maximum data entries associated with this History control entry stored in RMON. The range is from 1 to 3600,
default value is 50.
Buckets Granted: The number of data that will be saved in the RMON.
Buttons
Delete: Check to delete the entry. It will be deleted during the next save.
Add New Entry: Click to add a new entry.
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
12.4.2 STATUS
This page provides an overview of RMON History entries. Each page shows up to 99 entries from the History table, default is 20,
selected through the “entries per page” input field. When first visited, the web page will show the first 20 entries from the beginning of
the History table. The first displayed will be the one with the lowest History Index and Sample Index found in the History table.
The “Start from History Index and Sample Index” allows the user to select the starting point in the History table. Clicking the Refresh
button will update the displayed table starting from that or the next closest History table match.
The Next Entry will use the last entry of the currently displayed entry as a basis for the next lookup. When the end is reached, the text
“No more entries” is shown in the displayed table. Use the First Entry button to start over.