CHAPTER 12: SNMP
FIGURE 12-6. SNMP ACCESS CONFIGURATION
PARAMETER DESCRIPTION
Group Name: A string identifying the group name that this entry should belong to. The allowed string length is 1 to 31, and the allowed
content is ASCII characters from 33 to 126.
Security Model: Indicates the security model that this entry should belong to. Possible security models are:
Any: Any security model accepted (v1|v2c|usm).
v1: Reserved for SNMPv1.
v2c: Reserved for SNMPv2c.
usm: User-based Security Model (USM).
Security Level: Indicates the security model that this entry should belong to. Possible security models are:
NoAuth, NoPriv: No authentication and no privacy.
Auth, NoPriv: Authentication and no privacy.
Auth, Priv: Authentication and privacy.
Read View Name: The name of the MIB view defining the MIB objects for which this request may request the current values. The
allowed string length is 1 to 31, and the allowed content is ASCII characters from 33 to 126.
Write View Name: The name of the MIB view defining the MIB objects for which this request may potentially set new values. The
allowed string length is 1 to 31, and the allowed content is ASCII characters from 33 to 126.
Buttons
Add New Entry: Click to add a new entry. Specify the name and configure the new entry. Click “Apply.”
Delete: Check to delete the entry. It will be deleted during the next save.
Apply: Click to save changes.