Installing the Inverter
20
GM2 Series VFD
890054-00-00
Input Terminal Labels and Descriptions
Category
Terminal
Labels
Name
Description
Multi-
function
(digital)
terminal
configuration
P1
–
P5
Multi-function
(digital) Input 1-5
Configurable multi-function (digital) input
terminals.
Factory defaults are setup as follows:
•
P1: Fx
•
P2: Rx
•
P3: BX
•
P4: RST
•
P5: Speed-L
CM
Sequence
common terminal
Common terminal for multi-function (digital)
terminals, RS-485 communication, and analog
inputs and outputs.
Analog input
VR
12V source
terminal for
frequency
reference setting
Source voltage for reference frequency via
analog voltage input.
•
Maximum Voltage Output: 12 V
•
Maximum Current Output: 100 mA
•
Potentiometer:
1/5 kΩ
V1
Frequency setting
(voltage) terminal
Voltage input for 0 - 10V reference frequency.
•
Unipolar: 0
–
10 V (12 V Max.)
•
Bipolar: -10
–
10 V (±12 V Max.)
Summary of Contents for RSi GM2 Series
Page 2: ...ii...
Page 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Page 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Page 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Page 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...