217
Table of Functions
890054-00-00
GM2 Series VFD
Code
Comm.
Address
Name
Setting Range
Initial
Value
Property*
V/F SL
Ref.
source
1
Keypad-2
2
V1
4
V0
5
I2
6
Int 485
8
FieldBus
Cn.54
2
0h1436
Positive
direction
+torque limit
0.0
–200.0 (%)
180
O
X
O
Cn.55
2
0h1437
Positive
direction
regeneration
(-) torque limit
0.0
–200.0 (%)
180
O
X
O
Cn.56
2
0h1438
Reverse
direction
regeneration
(-) torque limit
0.0
–200.0 (%)
180
O
X
O
Cn.57
2
0h1439
Reverse
direction
+torque limit
0.0
–200.0 (%)
180
O
X
O
Cn.70
0h 1446
Speed search
mode
selection
0
Flying Start-1
3
0
X
O
O
1
Flying Start-2
Flying
Start-1
Cn.71
0h1447
Speed search
operation
selection
bit
0000
–1111
0000
[4]
X
O
O
1
Selects the speed
search function at
acceleration.
10
Initialization after a
fault
100
Restart after
instantaneous
power interruption
1000
Starting with
power-on
Cn.72
5
0h1448
Speed search
reference
current
80
–200 (%)
150
O
O
O
Cn.73
6
0h1449
Speed search
proportional
gain
0
–9999
Flying
Start-1
O
O
O
: 100
Flying
Start-2
: 600
7
Cn.74
6
0h144A
Speed search
integral gain
0
–9999
Flying
Start-1
O
O
O
: 200
Flying
Start-2
: 1000
Summary of Contents for RSi GM2 Series
Page 2: ...ii...
Page 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Page 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Page 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Page 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...