Technical Specification
890054-00-00
264
GM2 Series VFD
Derating based on Carrier Frequency
The continuous rated current of the inverter is limited based on the carrier frequency setting.
Parameter Cn.04 allows for adjustment of the carrier frequency. The default setting is 2 kHz or 3
kHz depending on Load type (Normal or Heavy). Refer to the following table for derating of output
current for carrier frequency settings above 4 kHz.
Inverter Capacity
Current Derating %
Normal Duty
Heavy Duty
Carrier Frequency (kHz.)
kW
HP
kW
HP
1~4
5~6
9
12
15
3-phase
240V
0.75
1
0.4
0.5
100
100
91
81
72
1.5
2
0.75
1
100
100
91
81
72
2.2
3
1.5
2
100
100
91
81
72
4
5
2.2
3
100
100
91
81
72
5.5
7.5
4
5
100
93
83
73
62
7.5
10
5.5
7.5
100
93
83
73
62
11
15
7.5
10
100
91
79
69
58
3-phase
480V
0.75
1
0.4
0.5
100
100
91
81
72
1.5
2
0.75
1
100
100
91
81
72
2.2
3
1.5
2
100
100
91
81
72
4
5
2.2
3
100
100
91
81
72
5.5
7.5
4
5
100
100
85
70
58
7.5
10
5.5
7.5
100
93
83
73
62
11
15
7.5
10
100
89
72
59
48
Summary of Contents for RSi GM2 Series
Page 2: ...ii...
Page 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Page 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Page 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Page 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...