Parameter Save
Changes to parameter settings in the compatible common area are not saved in the inverter
memory. If power is cycled, changes will be lost. Set dr.92 to 1 (Parameter Save) to save the
changed parameters into the inverter memory. The parameters cannot be saved if the inverter is
operating.
Group Code
Name
Setting
Setting
Range
Unit
dr
92 Parameter save
0 None
0~1
-
1
Parameter
save
Parameter Initialization
The parameters changed by the user can be initialized to the factory default settings. Initialize
parameters in all groups by selecting 1 (All GRP) or select specific groups . The parameters cannot
be initialized if the inverter is operating or during a fault condition.
Group Code
Name
Setting
Setting
Range
Unit
dr
93 Parameter initialization
0 No
0
–
14
-
Parameter Initialization Setting Details
Code and
Features
Description
dr.93
Parameter Init
Configuration
Function
0
No
-
1
Initialize all groups
Initialize all data. Select 1 (All Grp) and
press [PROG/ENT] key to start
initialization. On completion, 0 (No) will
be displayed.
2
Initialize dr group
Initialize data by groups. Select initialize
group and press [PROG/ENT] key to start
initialization. On completion, 0 (No) will
be displayed.
3
Initialize bA group
4
Initialize Ad group
5
Initialize Cn group
6
Initialize In group
7
Initialize OU group
8
Initialize CM group
9
Initialize AP group
11 Initialize AO group
12
Initialize Pr group
13 Initialize M2 group
14 Initialize Operation
Group
Summary of Contents for RSi GM2 Series
Page 2: ...ii...
Page 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Page 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Page 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Page 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...