Technical Specification
255
890054-00-00
GM2 Series VFD
Product Specification Details
Items
Description
Control
Control method
V/F control, Sensorless Vector, Slip Compensation
Frequency
settings resolution
Digital command: 0.01 Hz
Analog command: 0.06 Hz (60 Hz standard)
Frequency
accuracy
1% of maximum output frequency
V/F pattern
Linear, Square Reduction, User V/F
Overload capacity
Normal Duty: 120%, 1minute
Heavy Duty: 150%, 1 minute
Torque boost
Manual torque boost, Automatic torque boost
Operation
Operation Type
Start/Stop
Keypad, terminal strip, or communication operation
Frequency
settings
Analog type: -10
–10 V (bipolar), 0–10 V, 4–20 mA
Digital type: keypad
Operation
functions
Basic
Advanced
Start/Stop Operation
Auto Tuning
Frequency Reference Sources Sensorless Vector Control
Accel/Decel Times
Torque Limits
2nd Source (HOA)
Slip Compensation
Multi-Step Speeds
PID Control
Jog
Auxiliary Frequency Reference
Auto Start
Multi-Step Accel/Decel Times
Auto Reset/Restart
User V/Hz.
Accel/Decel Patterns
Dwell Frequency Operation
V/Hz. Control
Regen Avoidance
Liniear, Squared
Stall Prevention
Motor Rotation Prohibit
Speed Search
Torque Boost
VFD Fan Control
Start Modes
Loss of Power
Stop Modes
Ride Through (KEB)
Frequency Limits
Safe Stop
Jump Frequencies
Braking
3-Wire Control
DC Injection, Power Braking
Fire Mode
Flux Brakinig, External Brake
Input
(5) Multi-
function
terminals
(P1 - P5)
Select PNP (Source) or NPN (Sink) mode.
Functions of the digital inputs are set with parameters In.65
– In.69.
• Forward/Reverse
• Run Enable (Interlock)
• Reset
• External trip
• Emergency stop
• Jog operation (FWD/REV)
• Multi-Step frequencies
• Multi step acc/dec
• DC braking during stop
• Second motor selection
• Frequency increase
• Up/Down Frequency
• 3-wire
• Analog Hold (frequency)
Summary of Contents for RSi GM2 Series
Page 2: ...ii...
Page 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Page 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Page 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Page 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...