SpinLite® Full Side Washer
1MANUL961
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
50
Installation
Utilities
Pneumatic Connections: Air Panels to Cylinders
10) Measure the distance from the tee to the Cylinder on the driver side and passenger side
SpinLite® FSW.
Cut two 1/4” gray airlines, one for each FSW, to the measured length.
11) Connect the airlines to the tee fitting and route them to the appropriate SpinLite® FSW.
12) Connect each airline to the retract port on the Arm Cylinder, refer to the image below.
Electrical Connections: Air Panel to Controller
1) Supply 110 VAC to the retract valve on the air regulation panel from the carwash controller
unit.
CAUTION
It is recommended that a licensed electrician is contracted to perform all electrical installations.
All utilities MUST be installed in accordance with all local and national codes.
110 VAC in
Retract Port with
Flow Control Valve
Driver Side
Step 12
This image shows routing the gray ¼” Cylinder
Retract Airline to the driver side FSW unit;
repeat for the passenger side FSW unit.
Extend Port with
Flow Control Valve