SpinLite® Full Side Washer
1MANUL961
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
51
Installation
Utilities
Pneumatic Connections: Initial Air Settings for Air Panel
After hooking up all of the air connections verify that the extend and retract functions are working
properly for both the driver and passenger side SpinLite® FSW assemblies.
1) Extend both driver and passenger side SpinLite® FSW Arm assemblies and adjust the Extend
Pressure Regulators on the Cylinder Air Panel to an initial setting of 90 psi.
2) Set the Retract Pressure Regulator on the Air Panel to an initial setting of 20 psi this setting
should pivot the SpinLite® FSW Arm assemblies out of the way fast enough without slamming.
3) Additional fine-tuning of the Cylinder air circuits can be achieved by using the Manual Over-
Ride on the Air Panel Retract Valve, see above. Or, by using the flow control valves on the
Arm Cylinder Extend and Retract Ports on each of the SpinLite® FSW assemblies. Start with
Flow Controls set wide open.
Note:
Too much pressure will cause improper cleaning and may cause damage to vehicles.
Ideally no more than 2” of foam penetration on the vehicle’s side surface.
Manual Over-Ride
Retract Regulator
Initial Setting
20 PSI
Retract Valve
Main Air Supply
90-PSI minimum
120-PSI maximum
Extend Regulator
Initial Setting
90 PSI
Extend Regulator
Initial Setting
90 PSI