SpinLite® Full Side Washer
1MANUL961
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
11
Inspection
Equipment to Inspect Before Installation
Uncrate the SpinLite® Full Side Washer components and inspect for damage.
The SpinLite® FSW assemblies each have a 1HP 3-Phase motor that comes wired for the voltage selected
when ordered which was either 208/230, 460, or 575 VAC.
Before removing the SpinLite® Full Side Washer components from the shipping pallets do the following:
verify that the motors have been wired to the correct voltage for the site and confirm that each of the Arm
Assemblies has a pre-routed LED Cable and Motor Cable.
1) Locate the two (2) Motor/Gearbox assemblies. Refer to the Motor Tag on the Motor to determine
the proper wiring for the site voltage.
2) Remove the Motor Cover to expose the Motor Wires, refer to the Wire Diagrams on the inside of
the Motor Cover to verify that the motor is wired properly.
Note:
If there is any damaged equipment, file a claim with the trucking company immediately.
Receiving party is responsible for filing claim with trucking company. Notify your local
distributor or Belanger, Inc. immediately if shipment is determined damaged or incomplete.
Motor
Cover
Showing Delta
∆
Motor Wiring for
208/230 VAC
Delta
∆
is used for sites with
208/230 VAC
“Y” is used for sites with
460 VAC
Motor Wiring
Diagrams
Motor Tag