Technical data • Individual components
88
Automation PC 3100 user's manual V0.60
Model number
5AC901.IUPS-01
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Weight
Approx. 28 g
Table 108: 5AC901.IUPS-01 - Technical data
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
The interface option is equipped with short circuit protection. This value does not apply to the connected battery unit.
3)
For detailed information, see the temperature tables in the user's manual.
3.6.3.3.1 Pinout
UPS interface
Pin
Assignment
1
Temperature sensor
2
Temperature sensor
3
-
4
+
Connector, 4-pin, male
1 2 3 4
Table 109: 5AC901.IUPS-00/-01 - Pinout
3.6.3.4 Installation
This module is installed using the materials included in delivery. For more information regarding installation, see
section "Installing the interface option" on page .